Ingersoll-Rand X4i Compressor ControllerFeatures:
As much as 20% to 60% of the energy used to run compressed air systems is wasted due to: Running more compressors than required whether fully loaded, partially loaded or unloaded; Maintaining elevated system pressure to providea safety margin for peak demand. Reduce Your Existing Equipment Operating Costs! Using the Ingersoll Rand X4I System Controller to manage a multi-compressor system creates opportunities for savings and increased reliability. Keeping compressors off-line until actually needed eliminates unloaded running costs and creates reserve capacity. The example provided shows an annual energy savings of 32%, based on 8,000 hours at 0.08 $/kWh. This example assumes a typical four 25 hp/18 kW system. Connectivity, Communication, Control The Ingersoll Rand X4I System Controller is the Nucleus of Your Air System. The Ingersoll Rand X4I System Controller is one solution that quickly pays for itself, without compromising any of your previous compressor or air system capital investments. But beyond paying dividends in energy savings, it also provides ancillary savings in terms of labor, maintenance and resource utilizationhere's how: |
Specifications : X4I System Controller
| Max. # Units : 4 Compressors
Dimensions : 9.45" x 11.45 x 6.0 (241 mm x 291 mm x 152 mm) Weight : 14 lbs. (6.4 kg) Mounting : Wall, 4 x Mounting Screws |
Enclosure
: IP65, NEMA 4
Power Supply : 115 VAC +/- 10% (60 Hz) , 230 VAC +/- 10% (50 Hz) Temperature : 32°F to 115°F (0°C to 46°C) Humidity : 0% to 95% Rh Non-Condensing |
PDF Documents : Brochure Specifications Sheet Mutiple air compressor Interconnection Guide
Anti-Cycling Continuous
monitoring of system pressure and rate of change, plus advanced control
algorithms, prevent unnecessary compressor cycling.
Priority Compressor Selection
Minimize energy requirements by using your least efficient units only
when absolutely necessary.
Variable Energy Control
Designate one or more compressors to carry the base load, and let one
variable speed compressor adjust the trim load as required.
Equal Hours Control
Ensure equal use of matching compressors regardless of fluctuating demand
requirements.
System Standby Maintain
compressors off-line to minimize losses due to system leaks in pressurized
systems idle during non-productive periods.
![]() |
Ingersoll-Rand 4-Logic ControllerFeatures
Rotary or Reciprocating control methodology 24/7 time clock set (stop/start time) By-Pass control In the event of control system power loss - revert to local compressor control Security lockout (tamper proof keypad) Simple installation & set up 80-hour battery backup in the event of a power failure Will work with any pressure switch controlled machines. (110/240V 50-60hz-control voltage) |
...
![]() |
Ingersoll-Rand
Intellisys
Energy Optimizer
ENHANCE
RELIABILITY
SAVE
ENERGY
INCREASE
PRODUCTIVITY
|
![]() |
Ingersoll-Rand
Air
System Controller
The Air System Controller
(ASC) provides a window into the compressor room by making the raw data
available to plant operators and managers in formats that are easy to understand
plus provide substantial ENERGY SAVINGS. The ASC utilizes a Machine Interface
(HMI) Software specifically designed by Ingersoll-Rand for Compressed Air
Systems.
FeaturesTotal System Control & Remote Monitoring Total System Control -
Compressors, Dryers, Cooling Towers, Pumps & Accessories
|
| System Requirements:
- Windows 2000 Server Software
|
Pentium IV PC or Server1.4 GHz CPU 256 MB RAM 40 GB Hard Drive Ethernet Card CD-ROM Drive |
![]() |
Ingersoll-Rand
Air
System Manager
The Air System Manager (ASM) provides a window into the compressor room by making the raw data available to plant operators and managers in formats that are easy to understand plus provide substantial ENERGY SAVINGS. The ASM utilizes an "off-the-shelf" Machine Interface (HMI) Software which is specifically customized for Compressed Air Systems. Functions include: FeaturesTotal System Control & Remote Monitoring Total System Control -
Compressors, Dryers, Cooling Towers, Pumps & Accessories
|
| System Requirements:
Wonderware InTouch (standard)
|
Pentium IV PC or Server
1.4 GHz CPU 256 MB RAM 40 GB Hard Drive Ethernet Card CD-ROM Drive |
![]() |
Ingersoll-Rand
Intelliflow
Features SAVE ENERGY
INCREASE PRODUCTIVITY
ENHANCE RELIABILITY
|
|
Ingersoll-Rand
CMC
Control Panel Retrofits
The Ingersoll-Rand CMC Microcontroller was designed and developed to control and monitor a variety of equipment. Ingersoll-Rand owns the hardware design as well as the state-of-the-art software algorithms. An ISO 9001 supplier manufactures it to Ingersoll-Rands strict quality standards. The CMC utilizes an easy to program ladder logic format which allows it to be retrofitted on virtually any product. FeaturesPerforms all control
and monitoring functions
|
|
240 x 128 Graphical LCD screen Easy to Read - Folders & Pages design Touch Pad Overlay Multiple Language Support (over 24 supported) Universal Communications Module (UCM) |
Connect up to 3 Communication Modules
Access to all parameters Modbus and DF1 internally supported Modbus Plus & Profibus through communication cards |
![]() |
Ingersoll-Rand
Intellisys
Systems Manager
Features ENHANCE RELIABILITY
SAVE ENERGY
INCREASE PRODUCTIVITY
|